Currency:

Honeywell Midas Sensor Cartridge - Hydrogen Chloride (HCl) & Boron Trichloride (BCl3), Dichlorosilane (H2Cl2Si), Hydrogen Bromide (HBr) 

 

Require Install, Commissioning, Calibration or Servicing?

Safety Gear Store are able to install, commission and service your fixed gas detection system. We offer a professional service from fully trained, certified and manufacturer approved engineers, we are also one of the only suppliers with engineers that carry spares in their vehicles to ensure a quick and efficient service that will enable you to continue using your facility.

For more information on what we offer please visit one of the below pages: 

Fixed Gas Detection System Install and Commissioning

 Fixed Gas Detection System Calibration and Servicing



Gas Measured:Hydrogen Chloride (HCI)
Part No.:MIDAS-S-HCL
Sensor Technology:3 electrode electrochemical cell
Measuring Range (ppm):HCI 0 – 8ppm
Minimum Alarm 1 Set Point:1ppm
Repeatability:< ± 10% of measured value
Linearity:< ± 20% of measured value
Response Time:t62.5 < 30 seconds based on 3 min. exposure t90 < 140 seconds based on 3 min. exposure
Sensor Cartridge Life Expectancy:24 months under typical application conditions

Operating Temperature:

Effect of Temperature

    Zero

    Sensitivity

0°C to +40°C (32°F to 104°F)

< ± 0.001ppm / °C (0°C to 20°C)

< ± 0.005ppm / °C (20°C to 40°C)

< ± 0.4% of measured value / °C

Operating Humidity:20 – 75% rH
Operating Pressure:90 – 110kPa
Effect of Position:No effect in typical application
Calibration Gas:Hydrogen Chloride (4-6ppm HCI)
Challenge Gas (Bump Test):Hydrogen Chloride (4-6ppm HCI)
Warm Up Time:< 20 minutes

 

 

Midas HCI Group Sensor Cartridge Spec Sheet

Products specifications
Attribute nameAttribute value
Gases DetectedBoron Trichloride (BCl3), Dichlorosilane (H2SiCl2), Hydrogen Bromide (HBr), Hydrogen Chloride (HCI)

Honeywell Midas Sensor Cartridge - Boron Trichloride (BCl3 ), Dichlorosilane (H2Cl2Si), Hydrogen Bromide (HBr) Hydrogen Chloride (HCl)

Detects 4 types of gas:
Boron Trichloride (BCl3 ), Dichlorosilane (H2Cl2Si), Hydrogen Bromide (HBr) Hydrogen Chloride (HCl)
Manufacturer: Honeywell
SKU: MIDAS-S-HCL
£180.00 excl vat £216.00 inc vat

Honeywell Midas Sensor Cartridge - Boron Trichloride (BCl3 ), Dichlorosilane (H2Cl2Si), Hydrogen Bromide (HBr) Hydrogen Chloride (HCl)

£180.00 excl vat £216.00 inc vat
Picture of Fast Delivery

Fast Delivery

Next day delevery for shown as in stock orders placed before 1:00pm

Picture of Worldwide Shipping

Worldwide Shipping

Place a purchase order, Call or email to get an international shipping quote

Picture of Secure Online Purchasing

Secure Online Purchasing

SECURED BY SECTIGO (We do not accept AMEX)

Picture of Technical Support

Technical Support

Call or email to speak to a member of the technical team