SKU
XNX-AMSV-FHCB1

Honeywell XNX, XNX-AMSV-FHCB1 Universal Transmitter

Explosion-Proof Transmitters
£1,281.00 £1,537.20

XNX™ Universal Transmitter

XNX Stainless Steel Gas Detector ATEX/IECEx/INMETRO with MPD Catalytic Sensor 0-100%LEL

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted 316SS, includes MPD catalytic sensor 0-100%LEL

XNX Universal transmitter including MPD sensor and sensor cartridge.

Each gas detector (transmitter and MPD sensor) is supplied with blanking

plugs, magnetic wand/screwdriver tool, hex keys, electrical jumpers,

printed quick start guide and CD-ROM.

Please order any optional accessories seperatley.

The XNX Universal Transmitter, now with HART EDDL, marks a new turn in gas detection from Honeywell Analytics. It supports the widest range of sensors on a common platform and offers a modular choice of inputs and outputs.

Supports the widest range of sensors on a common platform and offers a modular choice of inputs and outputs (saving customers time and money).
 
Features & Benefits
  • Flammable gas detection 0 to 100% LFL/LEL
  • Flexible operation options
  • Minimal training required
Quick Specs
  • Material: LM25 aluminum, painted (SS316 painted optional)
  • Temperature: -40° to +65°C / -40° to +150°F (sensor dependent)
  • Humidity: 20 to 90% RH (non-condensing) 

Product Overview

XNX's advantage comes from a simple-to-use, low-maintenance universal platform that works with other safety equipment on a digital bus system, including Honeywell Analytics’ own Searchline Excel, Optima or other gas detectors, industry standard PLCs and third-party gas monitoring controllers. 

XNX supports Electrochemical, Infrared and Catalytic Bead gas monitors and uses standard 4-20mA wiring and HART; options include Modbus, Fieldbus (pending) up to three relays and a local Hart Adapter for configuration and diagnostics using existing HART handheld devices.  

With 200+ unique configurations, XNX satisfies Class 1/Class 2 intrinsically safe, explosion-proof requirements in upstream/downstream oil, chemical, wastewater and other industries. 

The enclosure is available in stainless steel or aluminum, with a marine-grade coating. Five threaded ports, available in metric or NPT versions, and ruggedized mounting options provide ultimate installation flexibility.  Instrumentation built on various sensing technologies can be attached locally to the transmitter or remotely with the appropriate accessories.

Data Sheet

 

Other options in this range are available please call for pricing 0800 678 5708
 

XNX Aluminum Transmitter ATEX/IECEx/INMETRO with MPD Catalytic Sensor 0-100%LEL

Part Number

Description

XNX-AMAV-NNCB1

XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

XNX-AMAV-NHCB1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

XNX-AMAV-RNCB1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

XNX-AMAV-RHCB1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

XNX-AMAV-MNCB1

XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

XNX-AMAV-MHCB1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

XNX-AMAV-FNCB1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

XNX-AMAV-FHCB1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

 

 

XNX Stainless Steel Transmitter ATEX/IECEx/INMETRO with MPD Infrared Hydrocarbon (Propane) Sensor 0-100%LEL

Part Number

Description

XNX-AMSV-NNIF1

XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted 316SS, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-AMSV-NHIF1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted 316SS, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-AMSV-RNIF1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/IECEx/INMETRO, 4 x M25 entries, painted 316SS, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-AMSV-RHIF1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted 316SS, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-AMSV-MNIF1

XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted 316SS, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-AMSV-MHIF1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted 316SS, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-AMSV-FNIF1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted 316SS, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-AMSV-FHIF1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted 316SS, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

 

 

XNX Aluminium Transmitter ATEX/IECEx/INMETRO with MPD Infrared Hydrocarbon (Propane) Sensor 0-100%LEL

Part Number

Description

XNX-AMAV-NNIF1

XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-AMAV-NHIF1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-AMAV-RNIF1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-AMAV-RHIF1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-AMAV-MNIF1

XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-AMAV-MHIF1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-AMAV-FNIF1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-AMAV-FHIF1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

 

 

XNX Stainless Steel Transmitter ATEX/IECEx/INMETRO with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V).

Part Number

Description

XNX-AMSV-NNIV1

XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted 316SS, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-AMSV-NHIV1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted 316SS, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-AMSV-RNIV1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/IECEx/INMETRO, 4 x M25 entries, painted 316SS, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-AMSV-RHIV1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted 316SS, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-AMSV-MNIV1

XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted 316SS, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-AMSV-MHIV1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted 316SS, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-AMSV-FNIV1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted 316SS, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-AMSV-FHIV1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted 316SS, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

 

 

XNX Aluminium Transmitter ATEX/IECEx/INMETRO with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V).

Part Number

Description

XNX-AMAV-NNIV1

XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-AMAV-NHIV1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-AMAV-RNIV1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-AMAV-RHIV1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-AMAV-MNIV1

XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-AMAV-MHIV1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-AMAV-FNIV1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-AMAV-FHIV1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

 

 

XNX Stainless Steel Transmitter ATEX/IECEx/INMETRO with MPD Infrared CO2 Sensor 0-5%V/V.

Part Number

Description

XNX-AMSV-NNIC1

XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted 316SS, includes MPD IR CO2 sensor 0-5%v/v

XNX-AMSV-NHIC1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted 316SS, includes MPD IR CO2 sensor 0-5%v/v

XNX-AMSV-RNIC1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/IECEx/INMETRO, 4 x M25 entries, painted 316SS, includes MPD IR CO2 sensor 0-5%v/v

XNX-AMSV-RHIC1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted 316SS, includes MPD IR CO2 sensor 0-5%v/v

XNX-AMSV-MNIC1

XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted 316SS, includes MPD IR CO2 sensor 0-5%v/v

XNX-AMSV-MHIC1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted 316SS, includes MPD IR CO2 sensor 0-5%v/v

XNX-AMSV-FNIC1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted 316SS, includes MPD IR CO2 sensor 0-5%v/v

XNX-AMSV-FHIC1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted 316SS, includes MPD IR CO2 sensor 0-5%v/v

 

 

XNX Aluminium Transmitter ATEX/IECEx/INMETRO with MPD Infrared CO2 Sensor 0-5%V/V.

Part Number

Description

XNX-AMAV-NNIC1

XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

XNX-AMAV-NHIC1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

XNX-AMAV-RNIC1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

XNX-AMAV-RHIC1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

XNX-AMAV-MNIC1

XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

XNX-AMAV-MHIC1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

XNX-AMAV-FNIC1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

XNX-AMAV-FHIC1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

 

 

XNX Stainless Steel Transmitter UL/CSA with MPD Catalytic Sensor 0-100%LEL

Part Number

Description

XNX-UTSV-NNCB1

XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries, painted 316SS, includes MPD catalytic sensor 0-100%LEL

XNX-UTSV-NHCB1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted 316SS, includes MPD catalytic sensor 0-100%LEL

XNX-UTSV-RNCB1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 4 x 3/4"NPT entries, painted 316SS, includes MPD catalytic sensor 0-100%LEL

XNX-UTSV-RHCB1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted 316SS, includes MPD catalytic sensor 0-100%LEL

XNX-UTSV-MNCB1

XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA, 4 x 3/4"NPT entries, painted 316SS, includes MPD catalytic sensor 0-100%LEL

XNX-UTSV-MHCB1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted 316SS, includes MPD catalytic sensor 0-100%LEL

XNX-UTSV-FNCB1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 4 x 3/4"NPT entries, painted 316SS, includes MPD catalytic sensor 0-100%LEL

XNX-UTSV-FHCB1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted 316SS, includes MPD catalytic sensor 0-100%LEL

 

 

XNX Aluminum Transmitter UL/CSA with MPD Catalytic Sensor 0-100%LEL

Part Number

Description

XNX-UTAV-NNCB1

XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

XNX-UTAV-NHCB1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

XNX-UTAV-RNCB1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

XNX-UTAV-RHCB1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

XNX-UTAV-MNCB1

XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

XNX-UTAV-MHCB1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

XNX-UTAV-FNCB1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

XNX-UTAV-FHCB1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

 

 

XNX Stainless Steel Transmitter UL/CSA with MPD Infrared Hydrocarbon (Propane) Sensor 0-100%LEL

Part Number

Description

XNX-UTSV-NNIF1

XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries, painted 316SS, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-UTSV-NHIF1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted 316SS, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-UTSV-RNIF1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 4 x 3/4"NPT entries, painted 316SS, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-UTSV-RHIF1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted 316SS, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-UTSV-MNIF1

XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA, 4 x 3/4"NPT entries, painted 316SS, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-UTSV-MHIF1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted 316SS, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-UTSV-FNIF1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 4 x 3/4"NPT entries, painted 316SS, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-UTSV-FHIF1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted 316SS, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

 

 

XNX Aluminium Transmitter UL/CSA with MPD Infrared Hydrocarbon (Propane) Sensor 0-100%LEL

Part Number

Description

XNX-UTAV-NNIF1

XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-UTAV-NHIF1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-UTAV-RNIF1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-UTAV-RHIF1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-UTAV-MNIF1

XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-UTAV-MHIF1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-UTAV-FNIF1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-UTAV-FHIF1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

 

 

XNX Stainless Steel Transmitter UL/CSA with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V).

Part Number

Description

XNX-UTSV-NNIV1

XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries, painted 316SS, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-UTSV-NHIV1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted 316SS, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-UTSV-RNIV1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 4 x 3/4"NPT entries, painted 316SS, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-UTSV-RHIV1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted 316SS, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-UTSV-MNIV1

XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA, 4 x 3/4"NPT entries, painted 316SS, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-UTSV-MHIV1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted 316SS, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-UTSV-FNIV1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 4 x 3/4"NPT entries, painted 316SS, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-UTSV-FHIV1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted 316SS, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

 

 

XNX Aluminium Transmitter UL/CSA with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V).

Part Number

Description

XNX-UTAV-NNIV1

XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-UTAV-NHIV1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-UTAV-RNIV1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-UTAV-RHIV1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-UTAV-MNIV1

XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-UTAV-MHIV1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-UTAV-FNIV1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-UTAV-FHIV1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

 

 

XNX Stainless Steel Transmitter UL/CSA with MPD Infrared CO2 Sensor 0-5%V/V.

Part Number

Description

XNX-UTSV-NNIC1

XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries, painted 316SS, includes MPD IR CO2 sensor 0-5%v/v

XNX-UTSV-NHIC1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted 316SS, includes MPD IR CO2 sensor 0-5%v/v

XNX-UTSV-RNIC1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 4 x 3/4"NPT entries, painted 316SS, includes MPD IR CO2 sensor 0-5%v/v

XNX-UTSV-RHIC1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted 316SS, includes MPD IR CO2 sensor 0-5%v/v

XNX-UTSV-MNIC1

XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA, 4 x 3/4"NPT entries, painted 316SS, includes MPD IR CO2 sensor 0-5%v/v

XNX-UTSV-MHIC1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted 316SS, includes MPD IR CO2 sensor 0-5%v/v

XNX-UTSV-FNIC1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 4 x 3/4"NPT entries, painted 316SS, includes MPD IR CO2 sensor 0-5%v/v

XNX-UTSV-FHIC1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted 316SS, includes MPD IR CO2 sensor 0-5%v/v

 

 

XNX Aluminium Transmitter UL/CSA with MPD Infrared CO2 Sensor 0-5%V/V.

Part Number

Description

XNX-UTAV-NNIC1

XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

XNX-UTAV-NHIC1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

XNX-UTAV-RNIC1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

XNX-UTAV-RHIC1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

XNX-UTAV-MNIC1

XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

XNX-UTAV-MHIC1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

XNX-UTAV-FNIC1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

XNX-UTAV-FHIC1

XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

 

 

XNX Stainless Steel Gas Detector CU-TR with MPD Catalytic Sensor 0-100%LEL

Part Number

Description

XNX-RMSV-NNCB1

XNX Gas Detector, HART® over 4-20mA output, CU-TR, 4 x M25 entries, painted 316SS, includes MPD catalytic sensor 0-100%LEL

XNX-RMSV-NHCB1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, CU-TR, 3 x M25 entries, painted 316SS, includes MPD catalytic sensor 0-100%LEL

XNX-RMSV-RNCB1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, Cu-TR, 4 x M25 entries, painted 316SS, includes MPD catalytic sensor 0-100%LEL

XNX-RMSV-RHCB1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, CU-TR, 3 x M25 entries, painted 316SS, includes MPD catalytic sensor 0-100%LEL

XNX-RMSV-MNCB1

XNX Gas Detector, HART® over 4-20mA and Modbus output, CU-TR, 4 x M25 entries, painted 316SS, includes MPD catalytic sensor 0-100%LEL

XNX-RMSV-MHCB1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, CU-TR, 3 x M25 entries, painted 316SS, includes MPD catalytic sensor 0-100%LEL

XNX Aluminum Transmitter CU-TR with MPD Catalytic Sensor 0-100%LEL

Part Number

Description

XNX-RMAV-NNCB1

XNX Gas Detector, HART® over 4-20mA output, CU-TR, 4 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

XNX-RMAV-NHCB1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, CU-TR, 3 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

XNX-RMAV-RNCB1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, CU-TR, 4 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

XNX-RMAV-RHCB1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, CU-TR, 3 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

XNX-RMAV-MNCB1

XNX Gas Detector, HART® over 4-20mA and Modbus output, CU-TR, 4 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

XNX-RMAV-MHCB1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, CU-TR, 3 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

 

 

XNX Stainless Steel Transmitter CU-TR with MPD Infrared Hydrocarbon (Propane) Sensor 0-100%LEL

Part Number

Description

XNX-RMSV-NNIF1

XNX Gas Detector, HART® over 4-20mA output, CU-TR, 4 x M25 entries, painted 316SS, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-RMSV-NHIF1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, CU-TR, 3 x M25 entries, painted 316SS, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-RMSV-RNIF1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, CU-TR, 4 x M25 entries, painted 316SS, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-RMSV-RHIF1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, CU-TR, 3 x M25 entries, painted 316SS, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-RMSV-MNIF1

XNX Gas Detector, HART® over 4-20mA and Modbus output, CU-TR, 4 x M25 entries, painted 316SS, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-RMSV-MHIF1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, CU-TR, 3 x M25 entries, painted 316SS, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

 

 

XNX Aluminium Transmitter CU-TR with MPD Infrared Hydrocarbon (Propane) Sensor 0-100%LEL

Part Number

Description

XNX-RMAV-NNIF1

XNX Gas Detector, HART® over 4-20mA output, CU-TR, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-RMAV-NHIF1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, CU-TR, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-RMAV-RNIF1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, CU-TR, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-RMAV-RHIF1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, CU-TR, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-RMAV-MNIF1

XNX Gas Detector, HART® over 4-20mA and Modbus output, CU-TR, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-RMAV-MHIF1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, CU-TR, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

 

 

XNX Stainless Steel Transmitter CU-TR with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V).

Part Number

Description

XNX-RMSV-NNIV1

XNX Gas Detector, HART® over 4-20mA output, CU-TR, 4 x M25 entries, painted 316SS, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-RMSV-NHIV1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, CU-TR, 3 x M25 entries, painted 316SS, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-RMSV-RNIV1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, CU-TR, 4 x M25 entries, painted 316SS, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-RMSV-RHIV1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, CU-TR, 3 x M25 entries, painted 316SS, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-RMSV-MNIV1

XNX Gas Detector, HART® over 4-20mA and Modbus output, CU-TR, 4 x M25 entries, painted 316SS, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-RMSV-MHIV1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, CU-TR, 3 x M25 entries, painted 316SS, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

 

 

XNX Aluminium Transmitter CU-TR with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V).

Part Number

Description

XNX-RMAV-NNIV1

XNX Gas Detector, HART® over 4-20mA output, CU-TR, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-RMAV-NHIV1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, CU-TR, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-RMAV-RNIV1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, CU-TR, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-RMAV-RHIV1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, CU-TR, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-RMAV-MNIV1

XNX Gas Detector, HART® over 4-20mA and Modbus output, CU-TR, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

XNX-RMAV-MHIV1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, CU-TR, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v)

 

 

XNX Stainless Steel Transmitter CU-TR with MPD Infrared CO2 Sensor 0-5%V/V.

Part Number

Description

XNX-RMSV-NNIC1

XNX Gas Detector, HART® over 4-20mA output, CU-TR, 4 x M25 entries, painted 316SS, includes MPD IR CO2 sensor 0-5%v/v

XNX-RMSV-NHIC1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, CU-TR, 3 x M25 entries, painted 316SS, includes MPD IR CO2 sensor 0-5%v/v

XNX-RMSV-RNIC1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, CU-TR, 4 x M25 entries, painted 316SS, includes MPD IR CO2 sensor 0-5%v/v

XNX-RMSV-RHIC1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, CU-TR, 3 x M25 entries, painted 316SS, includes MPD IR CO2 sensor 0-5%v/v

XNX-RMSV-MNIC1

XNX Gas Detector, HART® over 4-20mA and Modbus output, CU-TR, 4 x M25 entries, painted 316SS, includes MPD IR CO2 sensor 0-5%v/v

XNX-RMSV-MHIC1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, CU-TR, 3 x M25 entries, painted 316SS, includes MPD IR CO2 sensor 0-5%v/v

 

 

XNX Aluminium Transmitter CU-TR with MPD Infrared CO2 Sensor 0-5%V/V.

Part Number

Description

XNX-RMAV-NNIC1

XNX Gas Detector, HART® over 4-20mA output, CU-TR, 4 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

XNX-RMAV-NHIC1

XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, CU-TR, 3 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

XNX-RMAV-RNIC1

XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, CU-TR, 4 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

XNX-RMAV-RHIC1

XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, CU-TR, 3 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

XNX-RMAV-MNIC1

XNX Gas Detector, HART® over 4-20mA and Modbus output, CU-TR, 4 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

XNX-RMAV-MHIC1

XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, CU-TR, 3 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v

 

 

More Information
Free Shipping
No
Manufacturer's Suggested Retail Price
£0.00
To Top